6-GFM 1.2…200 12V
6-GFM-38…200 12V C
6-GFM-38…150 12V X
GFM-200…3900 2V Z
GFMG-100…3000 2V
GFD-200…3000 2V
GFM-200…3900 2V (Z) series

Sealed low
maintenance batteries
with charge equalizer
Applications:
|
Technology:
Voltage:
Capacity:
Number of D.O.D. cycles 60%:
Recommended discharge time:
Service life (at t=+20°C):
Positive electrode:
|
AGM;
2 V;
200 - 3900 Ah;
800;
5 min - 10 h;
no less than 15 years;
Pb-Ca-Sn lattice flat plates.
|
Îáëàñòü ïðèìåíåíèÿ
- Telecommunications.
- Trunk communications lines.
- Satellite communications systems.
- Cellular and mobile communications systems.
- Uninterruptible Power Supply (UPS).
- Power industry.
- Traffic organization and management systems.
- Rail way alarms, automatics and communications
systems.
- Oil-and-gas and mineral resource industry.
- Controls and automatics for electric generators.
Product characteristics
-
Low voltage floating charge without the need of
equalizing charge: 2.23V/cell·25C floating charge at constant voltage, without
the need of equalizing charge.
-
Ten-hour-rate capacity can be reached 100% for the
first cycle.
-
One-hour-rate capacity coefficient is 0.55, final
voltage is 1.75V.
-
Super performance of charge reception.
-
Self-discharge less than 3% for 28 days storage
period at normal temperature.
-
The pressure of opening and closing valves can be
adjusted precisely.
-
No changes occur on the pressure of the opening and
closing valves even after long-time use.
-
The acid filter can prevent liquid leakage and
explosion of batteries.
-
The terminals and the connect bars are shielded by
top covers to prevent accidental short circuit.
-
The heat sealing structure and resin sealing
structure with German resin are reliable.
Installation
-
Check tile mount of batlerics and accessories according to the packing list in
the box after unpacking the balteries. Please contract with Post Sales Service
Center immediately if there is a lack of
batteries or accessories.
-
Please clean and polish the terminal by brush made of steel wires so than t
the resistor of the connector to be lowest before connecting.
-
All batteries leave the factory wilh electric charge. Prohibit short circuit,
and mount by isolative tools to avid an electrical shock during the process of
mounting.
-
Afler finishing connection of the batteries group, check the total voltage of
hallery unit and putting of the poles to prevent from reversing the pole.
-
Disconnect batteries and power supply to prevent the batteries
over-discharging seriously even discarding as useless if dell not power on
immediately after finishing connection the batteries group.
-
Check the fastening screws for connecting batteries or output terminal to
prevent froml false connection resulting the connection voltage over drop even
burning batteries at higher current.
-
The charging equipment has the capacily to restrict the currenl at constant
voltage, with regulalor precision reaching +1% when charging.
Work condition
- The service life at ambient temperature i.e.15-25C is longer (coslight
battery can work at – 40 -50C).
- The charge equipment can charge at constant voltage with an accuracy of 1%.
- Coslight batteries can be installed horizontally or vertically.
Maintenance
- If it exceeds (2.24+0~m ) x nv/cell * 25C.(n refer to the number of celles
)the total floating charge voltage should be adjusted or the batteries' life
will be adversely affected.
- The floating charge voltage of single cell should be checked once a month and
the records need making carefully. If the differential of floating charge
voltage of single cell exceeds 0.05V/cell after it is used for six months,
please contact the manufacturer.
- The joint parts should be checked once a year. The loosed connection should be
deal with as soon as possible.
- The longer service life can be achieved if the balteries are used at the
ambient temperature of 15~C~25OC, GFM series of batteries can work under the
condition of -40C-50C.
- Neither Over discharge (discharge voltage lower than final voltage) nor over
charge(charge voltage higher than floaling charge for a long time)should be
allowed. The batteries should be charged immediately after their discharge or
the batteries' life will be adversely affected.
Time, voltage, current
and temperature should be recorded at every time of
discharge.
- Not organic solvent but the soap water is permitted to clean the surface of
the batteries. The dry cloth easily producing electrostatic should be avoided.
- If the batteries need to be stored, please disconnect the connection among the
charge equipment and the loads. The surrounding should be kept cool, dry and
ventilated.
Store and transport
- Be careful to avoid short circuit of batteries during their transportation
and installation, as they have been charged before leaving the factory.
- Avoid bumping and humidity during transport, load and unload the batteries.
- If the battery needs to be stored, the place for storage should be cool, dry
and ventilated.
Certification
-
International quality certificate
ISO 9001:2000.

Standard sizes for batteries of Coslight GFM (Z) series
|
Type |
Voltage
|
Capacity Ñ10 |
Dimensions |
Weight |
| |
V |
1.8
V/cell,
+20 Ñ |
Length,
mm |
Width,
mm
|
Height,
mm |
kg |
|
GFM-200Z |
2 |
200 |
94 |
176 |
367 |
15 |
|
GFM-260Z |
2 |
260 |
117 |
178 |
367 |
19 |
|
GFM-300Z |
2 |
300 |
144 |
179 |
367 |
22 |
|
GFM-400Z |
2 |
400 |
164 |
178 |
367 |
27 |
|
GFM-500Z |
2 |
500 |
215 |
181 |
368 |
35 |
|
GFM-650Z |
2 |
650 |
261 |
180 |
369 |
42 |
|
GFM-800Z |
2 |
800 |
318 |
179 |
369 |
52 |
|
GFM-1000Z |
2 |
1000 |
417 |
179 |
369 |
69 |
|
GFM-1300Z |
2 |
1300 |
513 |
182 |
369 |
85 |
|
GFM-1600Z |
2 |
1600 |
334 |
358 |
371 |
105 |
|
GFM-2000Z |
2 |
2000 |
425 |
358 |
371 |
136 |
|
GFM-2600Z |
2 |
2600 |
518 |
357 |
371 |
169 |
|
GFM-3000Z |
2 |
3000 |
616 |
358 |
371 |
206 |
|
GFM-3900Z |
2 |
3900 |
740 |
358 |
371 |
247 |
Discharge data for batteries of 6-GFM series
|
Battery
type |
Discharge time |
| |
10 min |
20 min |
30 min |
1 h |
2 h |
3 h |
5 h |
8 h |
10 h |
|
GFM-200Z |
335 |
252,2 |
158 |
107,4 |
65,8 |
50 |
33,6 |
24 |
20 |
|
GFM-260Z |
435,5 |
327,8 |
205,4 |
139,6 |
85,5 |
65 |
43,7 |
31,2 |
26 |
|
GFM-300Z |
502,5 |
378,3 |
237 |
161 |
98,7 |
75 |
50,4 |
36 |
30 |
|
GFM-400Z |
670 |
504,4 |
316 |
214,7 |
131,6 |
100 |
67,2 |
48 |
40 |
|
GFM-500Z |
837,5 |
630,5 |
395 |
268,4 |
164,5 |
125 |
84 |
60 |
50 |
|
GFM-650Z |
1089 |
819,6 |
513,5 |
348,9 |
213,9 |
162,5 |
109 |
78 |
65 |
|
GFM-800Z |
1340 |
1009 |
632 |
429,4 |
263,2 |
200 |
134 |
96 |
80 |
|
GFM-1000Z |
1675 |
1261 |
790 |
536,8 |
329 |
250 |
168 |
120 |
100 |
|
GFM-1300Z |
2178 |
1639 |
1024 |
697,8 |
427,7 |
325 |
218 |
156 |
130 |
|
GFM-1600Z |
2680 |
2017 |
1264 |
858,9 |
526,4 |
400 |
269 |
192 |
160 |
|
GFM-2000Z |
3350 |
2522 |
1580 |
1074 |
658 |
500 |
336 |
240 |
200 |
|
GFM-2600Z |
4355 |
3278 |
2054 |
1396 |
855,4 |
650 |
437 |
312 |
260 |
|
GFM-3000Z |
5025 |
3783 |
2370 |
1610 |
987 |
750 |
504 |
360 |
300 |
|
GFM-3900Z |
6533 |
4918 |
3081 |
2094 |
1283 |
975 |
655 |
468 |
390 |
|